DS924iPET (ITI # 60-511-02-95)
Learn Mode (LM) Wireless PIR Motion Sensor
Installation Instructions
AVOID
1.0 Overview
Hot or cold air
directed onto
sensor
Direct or
reflected
sunlight
The DS924iPET is a Passive Infrared (PIR) Motion Sensor designed to
detect movement in the interior of a structure by sensing the Infrared
energy emitted from the human body as it moves across the Sensor’s field
of view. When motion is detected the unit sends an alarm signal to the
Control Panel. The DS924iPET is a high performance PIR Motion Sensor
which uses advanced signal processing to provide outstanding catch
performance and unsurpassed false alarm immunity. The DS924iPET is
designed to ignore a dog up to 40 pounds, two cats and small rodents.
Figure 1
4.0 Mounting Procedure
4.1 Surface or Corner Mounting
2.0 Specifications
General
• Power is supplied by 3.6 VDC Lithium Battery. Saft LS14250
(0.85AH, 1/2AAbattery).
• Typical current draw is 12 micro-amps with LED disabled.
• Typical battery life is 5 years.
For Pet Applications, surface or corner mount the
detector. Do not use the optional swivel bracket.
IMPORTANT
• Operating temperature range of +32°F to +120°F (0°C to +49°C).
Don't
point
at
Don't
point
where
pets
PIR Motion Sensor
stairs
6.5 Ft
(2 M)
• Coverage area 35 ft. by 35 ft.
can
climb
• Internal coverage pointability +2° to -10° Vertical and ±10° Horizontal.
• Field selectable sensitivity options of Standard, Intermediate, or High.
• Three minute transmitter lockout time after alarm extends battery life.
• Timed Walk Test Mode automatically disables LED after setup to extend
battery life.
NO
NO
Mount the detector 6 1/2 feet
(2 meters) above the floor
Figure 2
• Remove the sensor’s cover by gently inserting a screwdriver into the
• Cover activated Tamper indication. Optional wall activated Tamper is
included.
COVER
notch at the bottom of the cover.
• Completely loosen the mounting
base locking screw.
• Remove the mounting plate from
the enclosure by prying it up
and out from the bottom.
• Punch out 2 appropriate holes
in the mounting plate (for
surface or corner applications).
HINGES
RF Transmitter
10
5
0
5
10
• Integral RF transmitter capable of transmitting at least 500 feet open air.
(Actual acceptable transmitter range should be verified for each
installation).
• Transmits low battery report (trouble) to the Control Panel.
• Transmits supervisory signal to the Control Panel every 64 minutes.
• Intended for use with listed compatible ITI Learn Mode control panels.
LENS
LENS
FRAME
WALK TEST LED
0
4
8
S
I
SENSITIVITY PINS
H
WALK TEST
SWITCH
TEST
3.0 Installation Guidelines
Do
Note: The wall tamper cannot
be used when corner
mounting.
VERTICALADJUST
SCREW
WALL TAMPER
BYPASS
JUMPER
TAMPER
SWITCH
MOUNTING BASE
LOCKING
COVER
LATCH
SCREW
• Keep all sensors within 100 feet of the Control Panel. The 100 foot
distance recommendation is given as a starting guideline. The LM PIR
Transmitter has an open air range of at least 500 feet, but the installation
environment may influence this range.
• Mount the sensor so there is a reference point (such as a wall) at the
end of its detection pattern.
• Mount the sensor so that an intruder will most likely walk across the
detection pattern.
• Mount the sensor 6.5 feet above the floor.
FRONT VIEW OF ENCLOSURE WITH COVER OFF
• If the wall tamper function is
Figure 3
required,
remove
the
rectangular knockout. Locate the small spring in the hardware kit. Hold
the PIR base so the battery is visible. Place the spring on the black plastic
shaft of the wall tamper switch just below the battery.
• Remove the wall tamper bypass jumper located next to the walk test
switch.
• Using the mounting plate as a template, mark the location of the required
holes on the mounting surface.
• For installation on drywall or plaster, drill a 1/8" pilot hole to determine if a
wall anchor is required.
• Mount on an insulated outside wall facing in.
• Mount on a surface which is rigid and free from vibration.
Don’t
• Secure the mounting plate to the wall with the #6 x 1" wood screws
provided.
• Mount in direct sunlight.
• Aim at air conditioners, heat vents, wood stoves, fireplaces, intermittent
heat sources, etc.
HINGE
• Aim at solar heated walls or uninsulated metal walls.
• Aim at normally moving objects (ceiling fans, pets over 40 pounds, etc.).
• Mount the sensor where it can be exposed to moisture.
• Mount in locations where the temperature may be outside the sensor’s
operating limits of +32°F to +120°F (0°C to +49°C).
• Mount in areas with large metallic surfaces (e.g. heating ducts) or electrical
wiring which may inhibit the sensor’s RF signals from reaching the
Control Panel.
CORNER
SURFACE
SURFACE
CORNER
CORNER
FLUSH
MOUNT
CORNER
MOUNT
KNOCKOUT
FOR
WALL TAMPER
• Mount in areas where the coverage may be blocked by any temporary
items such as boxes or freight.
TAB
MOUNTING
Figure 4
|